USCG Engineering General Subjects – Question Bank Book 11 (BK11) — page 24
3080 questions with correct answers from the official USCG question bank (2008 edition), book 11 (Engine – USCG question bank, 2008 edition, Engine officers). Pass mark 70%. Click a question to see its answer.
Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 2301.If you have a duplex single acting reciprocating pump making 150 strokes/minute, with a 5" diameter cylinder, a 12" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- 2302.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 13" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2303.As the drill bit is being fed into a metal work piece, a squeaking sound from the tip of the bit indicates __________.
- 2304.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 5" diameter cylinder, a 6" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2305.If you have a simplex single acting reciprocating pump making 190 strokes/minute, with a 6" diameter cylinder, a 4" stroke and operating with 88% volumetric efficiency, what is the capacity of this pump?
- 2306.Which of the following problems will cause a twist drill to cut improperly?
- 2307.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 5" diameter cylinder, a 9" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2308.If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- 2309.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 5" diameter cylinder, a 9" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2310.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 5" diameter cylinder, a 11" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2311.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 5" diameter cylinder, a 12" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 2312.Which of the fluids listed is suitable for use as a secondary refrigerant?
- 2313.If you have a duplex single acting reciprocating pump making 170 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2314.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 6" diameter cylinder, a 10" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2315.If you have a duplex single acting reciprocating pump making 180 strokes/minute, with a 3" diameter cylinder, a 11" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2316.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 6 diameter cylinder, a 11" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2317.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2318.In a refrigeration system, silica gel is used in the __________.
- 2319.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 13" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2320.Hidden edges in objects are represented in blueprints by __________.
- 2321.If you have a simplex single acting reciprocating pump making 100 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 82% volumetric efficiency, what is the capacity of this pump?
- 2322.If you have a simplex single acting reciprocating pump making 180 strokes/minute, with a 5" diameter cylinder, a 13" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2323.If you have a simplex single acting reciprocating pump making 130 strokes/minute, with a 4 diameter cylinder, a 12" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- 2324.The primary purpose of a thermostatic controlled solenoid valve used in a multi-box refrigeration system is to __________.
- 2325.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 2326.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- 2327.Cracks may be prevented from developing at the corners of welded plate inserts by __________.
- 2328.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 13" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2329.If you have a simplex single acting reciprocating pump making 190 strokes/minute, with a 5" diameter cylinder, a 11" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2330.The purpose of running a refrigeration compressor motor in short intermittent spurts when starting the system after a prolonged shutdown is to __________.
- 2331.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 7" diameter cylinder, a 13" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2332.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 4" diameter cylinder, a 13" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2333.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2334.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 5" diameter cylinder, a 6" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2335.If only the chill box solenoid valve remains open, the refrigeration compressor will eventually be stopped by __________.
- 2336.Careful handling of compressed gas bottles should include __________.
- 2337.Heat may be transferred by __________.
- 2338.If you have a simplex single acting reciprocating pump making 150 strokes/minute, with a 7" diameter cylinder, a 9" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- 2339.While reaming a hole, the reamer should not be turned backwards if the hole has not been fully reamed because __________.
- 2340.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 6 diameter cylinder, a 14" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2341.If your vessel burns 8 tons of fuel per hour at 15 knots, how many tons per hour will it burn at 18 knots?
- 2342.When two refrigerated spaces in a refrigeration system are served by a single compressor and condenser, yet are maintained at different temperatures, a back pressure regulating valve serves to provide __________.
- 2343.Which of the following conditions must be carried out before the superheating of saturated vapor can occur?
- 2344.Which of the following practices is considered to be safe for the handling and use of compressed gas cylinders?
- 2345.After a piece of pipe has been cut, a good shop practice to ream out the burr left in the pipe. This is done to __________.
- 2346.If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 5" diameter cylinder, a 8" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2347.An eroded globe valve disk can be repaired by __________.
- 2348.A graphite additive type grease is best suited for __________. I. low temperature applications II. high temperature applications
- 2349.The proper tool used for cutting new external threads is called a thread __________.
- 2350.In a vapor compression type refrigeration cycle, the refrigerant temperature decreases the most when passing through the __________.
- 2351.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 8 diameter cylinder, a 13" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2352.Oxygen and acetylene cylinders should always be stored __________.
- 2353.When internal threading for piping where the work permits the tap to be run entirely through you can begin and end the tapping of the hole by using a __________.
- 2354.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 5" diameter cylinder, a 11" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2355.When refering to greases, penetration number is____________.
- 2356.If the compressor is heard to knock while pumping down the low side for repairs, this is an indication of __________.
- 2357.Internal pipe threads are cut with __________.
- 2358.When using a hand die to cut threads on brass stock, the threads can be dry cut or may be lubricated with __________.
- 2359.If you have a duplex single acting reciprocating pump making 180 strokes/minute, with a 4" diameter cylinder, a 12" stroke and operating with 80% volumetric efficiency, what is the capacity of this pump?
- 2360.If you have a simplex single acting reciprocating pump making 120 strokes/minute, with a 4 diameter cylinder, a 12" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2361.When pipe is properly screwed into a tapped hole, it will give the correct fit when __________.
- 2362.A centrifugal pump designed to handle a liquid with a temperature of 250°F or greater must be provided with __________.
- 2363.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 4" diameter cylinder, a 13" stroke and operating with 77% volumetric efficiency, what is the capacity of this pump?
- 2364.A centrifugal pump with a double volute casing operated at greater than design capacity, will __________.
- 2365.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 13" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2366.If you have a duplex single acting reciprocating pump making 110 strokes/minute, with a 5" diameter cylinder, a 4" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- 2367.When repacking a reciprocating pump with more than four rings of packing, the packing is cut square, installed with the ends abutted, and each succeeding ring staggered with the butted ends __________.
- 2368.Which of the following problems will occur when the suction valve is throttled on a centrifugal pump not designed to operate in this manner?
- 2369.If you heard a 'crackling' sound occuring within a centrifugal pump, the most probable source of the noise would be the __________.
- 2370.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 6 diameter cylinder, a 11" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2371.If the flow of water from a centrifugal pump is allowed to be stopped by closing the discharge valve while the pump continues to run for an indefinite period, the __________.
- 2372.Which of the valves listed is normally closed when charging the refrigeration system through the high side?
- 2373.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2374.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 2375.If you have a duplex single acting reciprocating pump making 130 strokes/minute, with a 4 diameter cylinder, a 12" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- 2376.If a centrifugal pump is driven by a constant speed prime mover and produces a flow rate less than the designed specifications, the cause could be __________.
- 2377.You suspect a problem with the centrifugal fire pump on your ship, and begin to slowly close the discharge valve. Your suspicion is confirmed when the __________.
- 2378.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 7" diameter cylinder, a 13" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2379.The reset process control mode is also considered to be the same as __________. I. proportional speed floating control II. derivative control
- 2380.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 5" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 2381.The heat of compression is partially removed from compressed air by __________.
- 2382.In the operation of a proportional-plus-reset controller, the proportional action __________. I. aids the reset action during increasing error transients II. and the reset action are completely independent of one another
- 2383.If you have a duplex single acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 12" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2384.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 4 diameter cylinder, a 13" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2385.When one belt of a multiple V-belt drive requires replacing, it will be necessary to __________.
- 2386.Intercooling of a multistage air compressor provides the advantages of reducing the work of compression on the succeeding stages, and __________.
- 2387.If the intercooler of a low pressure air compressor becomes fouled either internally or externally, the __________.
- 2388.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 6" diameter cylinder, a 4" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2389.As a general rule of thumb, the reservoir used in a hydraulic system should have a capacity, when at the normal level, approximately equal to __________.
- 2390.Hydraulic system reservoirs should be maintained at recommended normal levels to reduce __________.
- 2391.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2392.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 6 diameter cylinder, a 14" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2393.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 11" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2394.The volumetric efficiency of a reciprocating air compressor, is the ratio of the __________.
- 2395.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 7" diameter cylinder, a 8" stroke and operating with 97% volumetric efficiency, what is the capacity of this pump?
- 2396.In a typical hydraulic system, return lines to the reservoir are terminated below the normal oil level to prevent __________. I. foaming of the oil II. condensation of warm oil vapors upon return
- 2397.If you have a simplex single acting reciprocating pump making 140 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 2398.In an atmosphere of 100% relative humidity, the wet bulb thermometer would register a temperature __________.
- 2399.In a typical hydraulic system, return lines to the reservoir are __________. I. terminated at or just above the normal level II. placed as far from the pump suction as possible
- 2400.The mandatory operating characteristic of a pure amplifier is the __________. I. form of the input and output energy must be the same II. ratio of the output change to input change must be a value greater than 1 (one)