USCG Engineering General Subjects – Question Bank Book 11 (BK11) — page 25
3080 questions with correct answers from the official USCG question bank (2008 edition), book 11 (Engine – USCG question bank, 2008 edition, Engine officers). Pass mark 70%. Click a question to see its answer.
Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 2401.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 8-inch diameter cylinder, a 13" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2402.The characteristic of 'offset' is inherent with which mode of control? I. proportional control II. reset control
- 2403.In the operation of a proportional-plus-reset controller, the proportional action __________. I. and the reset action are completely independent of one another II. opposes reset action during decreasing error transients
- 2404.A pneumercator measures the liquid level in a tank by sensing __________. I. head pressure II. liquid density
- 2405.If you have a duplex single acting reciprocating pump making 140 strokes/minute, with a 3" diameter cylinder, a 9" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2406.In the operation of a proportional-plus-reset controller, the proportional action __________. I. opposes the reset action during decreasing error transients II. aids the reset action during increasing error transients
- 2407.Which of the methods listed is most frequently used to control evaporator refrigerant flow rate in a shipboard refrigeration system?
- 2408.Reset control is considered to be the same as __________. I. proportional speed floating control II. integral control
- 2409.If you have a simplex single acting reciprocating pump making 250 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2410.If you have a simplex single acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 9" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2411.A compound Bourdon tube type pressure gage is capable of measuring __________.
- 2412.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 4-inch diameter cylinder, a 12" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2413.When the sensing bulb of a thermostatic expansion valve is charged with a fluid different from the charge used in the system, it is said to be __________.
- 2414.Energy imparted to the hydraulic fluid in an operating hydraulic system is stored in the __________.
- 2415.The baffle plates installed in the oil reservoir of a hydraulic system serve to __________.
- 2416.In order for the hydraulic pump installed in a constant flow system to maintain adequate flow, the pump suction should __________.
- 2417.If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 3" diameter cylinder, a 13" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2418.The instrument used to indicate the level of a fluid in a tank is called a __________.
- 2419.If you have a simplex single acting reciprocating pump making 210 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 77% volumetric efficiency, what is the capacity of this pump?
- 2420.If you have a simplex single acting reciprocating pump making 250 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 79% volumetric efficiency, what is the capacity of this pump?
- 2421.A hydraulic accumulator, used in a hydraulic system aboard a MODU, is designed to __________.
- 2422.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 6" diameter cylinder, a 11" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2423.If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2424.The component used in a hydraulic system to store potential energy in the form of hydraulic fluid under pressure, is the __________.
- 2425.A reservoir is used in a hydraulic system to __________.
- 2426.Which of the devices listed is considered to be a hydraulic system directional control valve?
- 2427.Which of the devices listed would be considered a hydraulic system directional control valve?
- 2428.Which of the devices listed would be considered a hydraulic system directional control valve?
- 2429.If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 4" diameter cylinder, a 13" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- 2430.A valve installed in a hydraulic system to manipulate the reversal of fluid flow, is called a __________.
- 2431.A valve installed in a hydraulic system to control the reversal of fluid flow is called a __________.
- 2432.If you have a duplex single acting reciprocating pump making 120 strokes/minute, with a 4" diameter cylinder, a 10" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2433.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 6" diameter cylinder, a 5" stroke and operating with 88% volumetric efficiency, what is the capacity of this pump?
- 2434.Which of the valves listed is not considered to be a hydraulic system directional control valve?
- 2435.If you have a duplex double acting reciprocating pump making 270 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2436.Which of the listed types of refrigeration compressors can be designed with short large diameter suction lines?
- 2437.If you have a duplex single acting reciprocating pump making 100 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 82% volumetric efficiency, what is the capacity of this pump?
- 2438.A hydraulic fluid flow control circuit, controlling linear actuator speed, with the pump operating below maximum operating pressure is known as the __________.
- 2439.A hydraulic fluid flow control circuit, controlling linear actuator speed during extension, with the pump operating at system pressure, is known as a __________.
- 2440.If you have a simplex single acting reciprocating pump making 250 strokes/minute, with a 4" diameter cylinder, a 6" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2441.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 7" diameter cylinder, a 11" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2442.A hydraulic fluid flow control circuit, used to control linear actuator speed during retraction, with the pump operating at above maximum pressure, is known as a __________.
- 2443.A dehydrator installed in a refrigeration system is used to remove __________.
- 2444.If you have a duplex double acting reciprocating pump making 160 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 2445.Directional control valves used in hydraulic systems may be positioned __________.
- 2446.If you have a duplex single acting reciprocating pump making 180 strokes/minute, with a 6" diameter cylinder, a 10" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 2447.Which of the listed pressure-control valves would be used in a hydraulic system to temporarily divert some, or all of the pump discharge until the additional flow was required?
- 2448.The determining factor for the strength of a flexible rubber hydraulic hose is the __________.
- 2449.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 6" diameter cylinder, a 5" stroke and operating with 88% volumetric efficiency, what is the capacity of this pump?
- 2450.Which of the listed materials can be used as a desiccant in a refrigeration system?
- 2451.A bent axis, variable stroke, axial piston pump produces a greater capacity than a comparable tilting box-type axial piston pump, because the __________.
- 2452.If you have a duplex single acting reciprocating pump making 180 strokes/minute, with a 6" diameter cylinder, a 5" stroke and operating with 98% volumetric efficiency, what is the capacity of this pump?
- 2453.Both the direction of flow and fluid flow rate of a variable displacement radial piston pump are determined by the relative positions of the __________.
- 2454.If you have a simplex single acting reciprocating pump making 170 strokes/minute, with a 5 diameter cylinder, a 4" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2455.If you have a simplex single acting reciprocating pump making 190 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 80% volumetric efficiency, what is the capacity of this pump?
- 2456.With an increase in temperature, the volume of hydraulic fluid __________.
- 2457.When normal operating pressure is applied to the hydraulic oil in a high-pressure system, the oil __________.
- 2458.Overheating of the hydraulic fluid in an electro-hydraulic anchor windlass, may indicate pump cavitation caused by __________.
- 2459.Cold storage compartments used for frozen or chilled foods, may be equipped with medium velocity air coolers to establish rapid convection and to __________.
- 2460.Overheating of the oil in a hydraulic system can be caused by __________.
- 2461.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 4" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 2462.Coast Guard Regulations require that OSV's under 100 GT must have a steering system that is capable of moving the ruddder __________.
- 2463.If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2464.If you have a simplex single acting reciprocating pump making 130 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2465.To prevent motor overload during start-up of a hermetically sealed centrifugal refrigeration system, the compressor suction gas variable inlet guide vanes remain __________.
- 2466.In a refrigeration system, if the cooling water to the condenser fails, the __________.
- 2467.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 4" diameter cylinder, a 8" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2468.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 4" diameter cylinder, a 8" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 2469.If a hydraulic pump is overheating, the cause may be __________.
- 2470.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 5" diameter cylinder, a 12" stroke and operation with 75% volumetric efficiency, what is the capacity of this pump?
- 2471.Capacity control of a centrifugal refrigeration compressor can be accomplished by __________.
- 2472.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 5" diameter cylinder, a 6" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 2473.A solenoid valve is operated by magnetic action through __________.
- 2474.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 6" diameter cylinder, a 9" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 2475.If you have a duplex single acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 12" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2476.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 11" stroke and operating with 77% volumetric efficiency, what is the capacity of this pump?
- 2477.When multiple refrigerated boxes are maintaining individual temperatures and supplied by a single refrigeration compressor, the individual box temperatures are controlled by the __________.
- 2478.A fluid power system is considered to be fail-safe if a component failure will result in __________. (46 CFR)
- 2479.If you have a duplex double acting reciprocating pump making 120 strokes/minute, with a 6" diameter cylinder, a 11" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2480.If you have a duplex double acting reciprocating pump making 160 strokes/minute, with a 7" diameter cylinder, a 13" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2481.If you have a simplex single acting reciprocating pump making 110 strokes/minute, with a 5" diameter cylinder, a 10" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 2482.If you have a duplex single acting reciprocating pump making 170 strokes/minute, with a 5" diameter cylinder, a 13" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2483.If you have a duplex single acting reciprocating pump making 180 strokes/minute, with a 4" diameter cylinder, a 12" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2484.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 6" diameter cylinder, a 4" stroke and operating with 88% volumetric efficiency, what is the capacity of this pump?
- 2485.If you have a duplex single acting reciprocating pump making 250 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 89% volumetric efficiency, what is the capacity of this pump?
- 2486.The lowest temperature at which fuel oil gives off sufficient vapor to burn continuously when ignited is defined as the __________.
- 2487.If you have a duplex double acting reciprocating pump making 120 strokes/minute, with a 4" diameter cylinder, a 12" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 2488.The flash point of bunker fuel is defined as the __________.
- 2489.If you have a simplex single acting reciprocating pump making 180 strokes/minute, with a 6" diameter cylinder, a 14" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2490.When a refrigeration compressor is in the 'off' cycle, the thermal expansion valve will_________.
- 2491.Some 'hot gas' defrost systems reheat the refrigerant just prior to its returning to the compressor to __________.
- 2492.The lowest temperature at which fuel oil gives off sufficient vapor to momentarily flash into flame when ignited is defined as the __________.
- 2493.If you have a duplex double acting reciprocating pump making 270 strokes/minute with 4" diameter cylinder, and a 7" stroke with 81% volumetric efficiency, what is the capacity of this pump?
- 2494.If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 7" diameter cylinder, a 11" stroke and operating with 87% volumetric efficiency, what is the capacity of this pump?
- 2495.If you have a duplex single acting reciprocating pump making 130 strokes/minute, with a 6" diameter cylinder, a 7" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- 2496.The tendency of a flamable liquid to vaporize is indicated by its __________.
- 2497.When using a chisel, you should __________.
- 2498.If you have a duplex single acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 5" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- 2499.The pressure in a low pressure refrigeration system about to be opened for repair should be __________.
- 2500.If you have a duplex single acting reciprocating pump making 250 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 79% volumetric efficiency, what is the capacity of this pump?