USCG Engineering General Subjects – Question Bank Book 11 (BK11) — page 18
3080 questions with correct answers from the official USCG question bank (2008 edition), book 11 (Engine – USCG question bank, 2008 edition, Engine officers). Pass mark 70%. Click a question to see its answer.
Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 1701.In a refrigeration system, the condenser cooling water regulating valve is directly controlled by the __________.
- 1702.In a refrigeration system, the component installed downstream of the thermal expansion valve is called the __________.
- 1703.Refrigerant recovery cylinders are color coded__________.
- 1704.The purpose of nozzles in a liquid mud system is to_________.
- 1705.A pneumercator is an instrument used to indicate __________.
- 1706.Movement of the material discharge hoses, fluctuating P-tank air pressure and a light dust trail from the receiving tank vent indicates __________.
- 1707.Why do OSV's with a liquid mud system generally have more than two tanks?
- 1708.In a liquid mud system, the sea valve must be tightly secured and not leak because___________.
- 1709.Which of the following steps should be taken before taking on a load of liquid mud for transport to a MODU?
- 1710.It is important to circulate the liquid mud on an OSV at regular intervals to___________.
- 1711.It is important to circulate liquid mud on an OSV to __________.
- 1712.Unless told otherwise by the mud dock representative, the recomended circulation time and rate for most new water based liquid mud for each tank is___________.
- 1713.A multiple evaporator coil unit is equipped with an evaporator back pressure regulating valve. This valve must be bypassed when pumping down the system for repairs because reduction of suction pressure would cause the valve to __________.
- 1714.The refrigerants referred to as CFC's are __________.
- 1715.All refrigerant recovered from burned out small appliances must be __________.
- 1716.Which of the following refrigerants is an interim retrofit replacement for R-11?
- 1717.Excess pressure used in a P-tank system will more than likely __________.
- 1718.In preparing to remove the air from a refrigeration condenser for a large multibox water cooled type III system, all of the refrigerant in the system should be __________.
- 1719.When recovering R-12 from a small appliance with a working compressor, using a recovery device manufactured after November 15, 1993, what percentage of the remaining charge must be removed from the system?
- 1720.Technicians servicing small refrigeration appliances can employ what type of recovery equipment?
- 1721.Which of the following represents a low-pressure refrigerant as defined by EPA regulation?
- 1722.What differentiates 'system-dependent' and 'self-contained' recovery devices in refrigeration systems?
- 1723.Overfilling a refrigerant container is extremely dangerous because of the high pressures generated. The generation of pressure is the __________.
- 1724.How do the modulating valves, found in some container refrigeration systems, differ in operation from solenoid valves found in the same system?
- 1725.All refrigeration systems must be protected with a __________.
- 1726.If passive recovery is used on a refrigeration unit with a non-operating compressor, the recovery should be made through____________.
- 1727.The process of removing refrigerant from a system and storing it without testing or processing is known as __________.
- 1728.Which of the following is not part of the high side of a refrigeration system?
- 1729.Refillable tanks used to ship CFC and HCFC refrigerants or used to recover these refrigerants must meet the standards of __________.
- 1730.If you find an extremely large refrigerant leak while using a halide torch, your flame will __________.
- 1731.How does a refrigeration solenoid valve differ from a modulating valve?
- 1732.Within the territorial limits fo the United States violations of the Clean Air Act of 1990, that includes the intentional release of R-11, R-12, R-22 and other related class I or class II substances may result in fines for each violation per day of __________.
- 1733.Operating a P-tank system with excessive pressure in the tank will most likely cause __________.
- 1734.Which of the following instruments can be used to measure the rate of air flow?
- 1735.When using nitrogen to pressure leak test a system, the nitrogen tank should always have a __________.
- 1736.Consultation should be made prior to beginning the conversion of an existing CFC-12 system to HFC-134a with __________.
- 1737.When air is at its dew point, it is at its __________.
- 1738.The movement of the armature within a modulating valve as used on some refrigeration systems is opposed by the __________.
- 1739.Which of the refrigerants listed is considered as a suitable replacement for R-11?
- 1740.If you have a simplex single acting reciprocating pump making 100 strokes/minute with 6" diameter cylinder, and an 11" stroke with 90% volumetric efficiency, what is the capacity of this pump?
- 1741.Persons recovering refrigerant from small appliances must be certified as a __________.
- 1742.Which of the refrigerants listed is considered as a suitable and limited ozone producing alternative for R-11?
- 1743.The air compressor for a P-tank unit should be operated for several minutes with its discharge valves open to the atmosphere to __________.
- 1744.As the amount of moisture in the air increases, the difference between the dry bulb and wet bulb temperatures will __________.
- 1745.Alkylbenzene ISO 32 cSt refrigerant oil is miscible and suitable to use with___________.
- 1746.Refrigerant leaks in a small shipboard water cooler __________.
- 1747.The speed of a belt driven ventilation fan can be increased without changing the motor speed by using a __________.
- 1748.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- 1749.All shipboard personnel responsible for the maintenance and repair of air conditioning systems must be certified through an approved Enviromental Protection Agency (EPA) program __________.
- 1750.Solenoid valves used in refrigeration systems may be classified as __________.
- 1751.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 5" diameter cylinder, a 7" stroke and operating with 96% volumetric efficiency, what is the capacity of this pump?
- 1752.If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 4" diameter cylinder, a 6" stroke and operating with 92% volumetric efficiency, what is the capacity of this pump?
- 1753.Small appliances with less than three pounds of refrigerant should be __________.
- 1754.The air compressor for a P-tank unit should be operated for several minutes with its discharge valves open to the atmosphere to __________.
- 1755.In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by __________.
- 1756.Moisture is removed from CFC-12 using a recycler by __________.
- 1757.Of the four refrigerants CFC-11, CFC-12, HFC-134a, and HCFC-22; HCFC-22 operates at the __________.
- 1758.The expansion valve used in a refrigeration system regulates the __________.
- 1759.The carbon ring of a refrigeration compressor crankshaft mechanical seal is held in position against the stationary ring by using a/an __________.
- 1760.If you have a simplex single acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 10" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- 1761.An untagged refrigerant cylinder is found in your storage area. It is light (sky) blue, and the refrigerant it contains is __________.
- 1762.In a refrigeration system, the bulb for the thermal expansion valve is always located __________.
- 1763.When installing a mechanical shaft seal on a refrigeration compressor, extreme care must be taken to prevent __________.
- 1764.What would be the result of throttling the suction valve to the point where the flow was less than that recommended by a centrifugal pump manufacturer? I. The designed discharge head would be reduced. II. The packing life would be greatly reduced.
- 1765.In order to maximize the performance of an operating centrifuge, you can adjust the fuel oil __________. I. viscosity II. through-put
- 1766.P-tank dry bulk material discharge hoses must be connected __________.
- 1767.Refrigeration systems using forced air circulation evaporators have a tendency to cause rapid dehydration of foods unless __________.
- 1768.The color of the refrigeration oil can indicate various operating conditions of the compressor/ refrigeration system in which it is used. Black oil can be an indication of __________.
- 1769.Potable and nonpotable water systems aboard ship __________.
- 1770.If you have a duplex double acting reciprocating pump making 190 strokes/minute, with a 3" diameter cylinder, a 12" stroke and operating with 90% volumetric efficiency, what is the capacity of this pump?
- 1771.HCFC-123 presents health threats to service technicians, which may include its __________.
- 1772.The oil observed in the sight glass of an operating refrigeration compressor appears to be brownish in color. This is indicative of __________.
- 1773.In addition to the recovery of refrigerant, recovery machines not necessarily able to pull a vacuum can also evacuate a system of __________.
- 1774.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 6" diameter cylinder, and a 10" stroke at an 80% volumetric efficiency, what is the capacity of this pump?
- 1775.If you have a simplex single acting reciprocating pump making 120 strokes/minute with a 5" diameter cylinder, a 5" stroke, and operating with a 93% volumetric efficiency, what is the capacity of this pump?
- 1776.CFC refrigerants exposed to high temperture or direct flame, will decompose and may produce __________.
- 1777.The purpose of the jet air line in a P-tank system is to __________.
- 1778.The color of the oil observed in the sight glass of an operating refrigeration compressor experiencing bearing wear or piston scoring would appear __________.
- 1779.A shot of anchor chain is equal to __________.
- 1780.A purge cycle is required on all low pressure chillers because __________.
- 1781.If you have a simplex single acting reciprocating pump making 200 strokes/minute with 3" diameter cylinder, a 4" stroke, and operating with a 93% volumetric efficiency, what is the capacity of this pump?
- 1782.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 6" diameter cylinder, a 7" stroke, operating with a 90% volumetric efficiency, what is the capacity of this pump?
- 1783.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 6" diameter cylinder, a 4" stroke, operating with a 90% volumetric efficiency, what is the capacity of this pump?
- 1784.If you have a simplex single acting reciprocating pump making 110 strokes/minute with a 7" diameter cylinder, a 8" stroke, operating with a 91% volumetric efficiency, what is the capacity of this pump?
- 1785.Which of the listed statements describes the reason why oil foaming occurs when starting a refrigeration compressor?
- 1786.What is the cooling medium used for most portable recovery unit condensers aboard ship?
- 1787.If you have a simplex single acting reciprocating pump making 190 strokes/minute with a 6" diameter cylinder, a 5" stroke, and operating with an 88% volumetric efficiency, what is the capacity of this pump?
- 1788.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 6" diameter cylinder, a 5" stroke, and operating with a 90% volumetric efficiency, what is the capacity of this pump?
- 1789.When a horizontal type centrifugal pump is used for dewatering the engine room bilges, you would __________. I. use a rotary, liquid piston type pump to obtain a prime II. partially open the sea suction valve, then gradually switch over to the required
- 1790.The most cost-effective method of recovering refrigerant from a chiller with more than 5 lbs of refrigerant, to meet EPA requirements is to use a __________.
- 1791.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 7" diameter cylinder, a 9" stroke, and operating at a 90% volumetric efficiency, what is the capacity of this pump?
- 1792.The bitter end is the __________.
- 1793.Which of the listed refrigerants has been more suitable than the others for use in a centrifugal refrigeration compressor?
- 1794.P-tanks on board a supply boat are filled through the __________.
- 1795.An estimated 15% of all refrigerant emissions from chillers occur during __________.
- 1796.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 7" diameter cylinder, an 11" stroke, and operating with a 90% volumetric efficiency, what is the capacity of this pump?
- 1797.If you have a simplex single acting reciprocating pump making 100 strokes/minute with a 7" diameter cylinder, a 12" stroke, and operating with a 90% volumetric efficiency, what is the capacity of this pump?
- 1798.If you have a simplex single acting reciprocating pump making 100 strokes/minute with 7" diameter cylinder, and a 13" stroke with a 90% volumetric efficiency, what is the capacity of this pump?
- 1799.In refrigeration systems, which type of contamination will the reclamation process be unable to separate?
- 1800.What is the maximum volume to which refillable refrigeration cylinders should be filled?