If you have a duplex double acting reciprocating pump making 170 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- A48 gpm ✓
- B40 gpm
- C24 gpm
- D12 gpm
Correct answer: A) 48 gpm