If you have a duplex single acting reciprocating pump making 130 strokes/minute, with a 4 diameter cylinder, a 12" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- A237 gpm
- B39 gpm
- C158 gpm
- D79 gpm ✓
Correct answer: D) 79 gpm