Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 101.To minimize corrosion, fuel oil strainer disks, spacers and scraper blades are made of __________.
- 102.Which of the following statements describes the function of an expansion tank in a diesel engine cooling system?
- 103.Prior to lighting off a cold automatically fired auxiliary boiler, you should __________.
- 104.Within the cycle of a forced circulation auxiliary water-tube boiler, part of the water flashes into steam, and the remaining hot water is __________.
- 105.Ignition failure in an automatically controlled auxiliary boiler could be caused by __________.
- 106.In a coil-type auxiliary water-tube circulation boiler __________.
- 107.One method of constructing large marine diesel engines and reducing the total engine frame weight is through __________.
- 108.On a large diesel engine installation, crankshaft axial alignment is maintained by the __________.
- 109.Which of the following statements is true concerning a main diesel engine oil cooler?
- 110.The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the __________.
- 111.Scavenging in a four-stroke/cycle diesel engine occurs during the __________.
- 112.A dirty atomizer sprayer plate in the burner of an auxiliary boiler, would be indicated by __________.
- 113.The color of the exhaust from a diesel engine should be __________.
- 114.Which of the following actions takes place in the control circuit of an automatically fired auxiliary boiler when the desired steam pressure is obtained?
- 115.In a large, slow-speed, main propulsion diesel engine, which of the parts listed is under tension when the engine is running?
- 116.Coast Guard Regulations regarding diesel fuel oil systems, valves for removing water or impurities are __________.
- 117.The lube oil cooler is located after the lube oil filter in order for __________.
- 118.The highest pressure in any closed diesel engine freshwater cooling system is at the __________.
- 119.Concerning diesel propelled vessels, the astern power is to provide for continuous operation astern __________.
- 120.Throttling a burner air register on an auxiliary boiler could result in __________.
- 121.A burner producing black smoke in an automatic auxiliary boiler, would be caused by a/an __________.
- 122.The main advantage of unit injectors over other fuel injection systems is __________.
- 123.Which action should be taken when an auxiliary boiler is in operation?
- 124.Failure of the burner flame in an automatic auxiliary boiler would probably be a result of __________.
- 125.If the flame of an automatically fired auxiliary boiler tends to move away from the burner tip when the firing rate is changed from low to high, you should __________.
- 126.In a two-stroke/cycle diesel engine, the process of scavenging begins as the __________.
- 127.Which of the following procedures decreases the total dissolved solids concentration in the water of an auxiliary boiler?
- 128.If the fire goes out in an automatically fired auxiliary boiler and the burner continues to supply fuel, there is a potential danger of __________.
- 129.Improper maintenance of an automatic auxiliary boiler oil burner could result in __________.
- 130.The bearings used to support the crankshaft of a diesel engine are generally called __________.
- 131.Which of the fuel systems listed combines the injection pump and the injection nozzle in one housing?
- 132.With respect to the flow of lubricating oil through a diesel engine, the lube oil coolers are located after filters in order to __________.
- 133.Maintaining the lowest possible scavenging air temperature at all times is not recommended due to the possibility of the __________.
- 134.The nuts of main bearings, connecting rod bolts and all other moving parts are to be secured by __________.
- 135.Most type(s) of microbiological growths in fuel are __________.
- 136.In accordance with Coast Guard Regulations (46 CFR), water level controls utilized in a small automatically fired auxiliary heating boiler, shall be tested __________.
- 137.After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the __________.
- 138.In a unit injector, an upper helix and lower helix are machined in the lower part of the plunger for __________.
- 139.Passages are drilled in the crankshafts of diesel engines to provide lubricating oil to the __________.
- 140.The outlet from an expansion tank of a closed freshwater cooling system should be piped to the __________.
- 141.The intake valves in a 4-stroke diesel engine are reseated by __________.
- 142.When preparing to light off a cold boiler equipped with a return flow fuel oil system, the re-circulating valve directs the flow of oil __________.
- 143.Small amounts of moisture are necessary to trigger the growth of microbiological organisms found in some marine fuels. Some sources of water contamination are __________.
- 144.Which of the following conditions will cause only one of the burner solenoid valves to close on an automatically fired, two burner unit, auxiliary boiler?
- 145.The main function of tie rods in the construction of large, low speed diesel engines is to __________.
- 146.On most modern diesel engines, the main and connecting rod bearings receive their lubricating oil by __________.
- 147.The expansion tank in a diesel engine closed freshwater cooling system is located at __________.
- 148.The burner assembly on an automatically fired auxiliary boiler fitted with variable capacity, pressure atomizing burners, maintains steam pressure by __________.
- 149.When accumulated carbon at the air inlet ports of a two-stroke/cycle diesel engine is being removed, you should take care to avoid carbon __________.
- 150.While an auxiliary boiler is operating at design load, which of the following actions will occur if the automatic combustion control system detects a steam pressure drop?
- 151.According to Coast Guard Regulations (46 CFR), when an automatically fired boiler has a flameout, which of the following actions should occur FIRST?
- 152.A sprayer plate used in a return flow fuel oil atomizer is correctly installed if the oil __________.
- 153.A unit type fuel injector is used on a diesel engine to __________.
- 154.Lubricating systems for diesel engines are usually designed to first provide a supply of lube oil to the engines __________.
- 155.If the valve tappets in a diesel engine are set at greater clearances than those specified by the engine manufacturer, those valves will __________.
- 156.Regarding a Diesel engine crankcase, the general arrangement and installation should preclude the possibility of __________.
- 157.The growth rate of microbiological organisms as found in some fuel supplies will __________.
- 158.The water in an auxiliary boiler should be chemically tested daily for alkalinity and __________.
- 159.The primary function of a flame safeguard system, as used on an automatically fired auxiliary boiler, is to prevent __________.
- 160.A diesel engine crankcase ventilation system __________.
- 161.Which of the fuel injection systems listed uses a spring loaded differential spray needle valve and an individual pump for each cylinder?
- 162.Proper lubrication of the main bearings is more easily obtained in a single acting four-stroke/cycle diesel engine than in a single acting two-stroke/cycle diesel engine because __________.
- 163.Increasing the valve clearance between a valve stem and rocker arm, will result in the valve __________.
- 164.Internal combustion engine crankcase vent outlets must be equipped with __________.
- 165.The purpose of designing some waste heat boilers with sinuous fire tubes, is to __________.
- 166.The amount of chloride content in the water of an auxiliary boiler can be reduced by __________.
- 167.What function is provided by the crankcase ventilation system on some diesel engines?
- 168.Fuel injection pumps using the port and helix metering principle requires the use of a __________.
- 169.Lubricating oil is supplied to the crankpin bearings in a marine diesel engine by __________.
- 170.Sacrificial zinc anodes are used on the saltwater side of diesel engine heat exchangers to __________.
- 171.The fuel supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler __________.
- 172.In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?
- 173.Constant capacity pressure atomizing fuel oil burners installed on automatically fired auxiliary boilers, respond to variations in load demand by __________.
- 174.Which of the following conditions could cause the feed pump for an auxiliary boiler to lose suction?
- 175.Coast Guard Regulations (46 CFR) specify that the fuel oil ignition system, on a small automatically fired auxiliary boiler, shall be energized __________.
- 176.The crankcases of many diesel engines are kept under a slight vacuum to __________.
- 177.The rate of cylinder lubricating oil metered to each cylinder of a large, low-speed, main propulsion diesel engine is __________.
- 178.On a medium-speed main propulsion diesel engine, the crankpin or crank journal bearings receive lubricating oil from __________.
- 179.The amount of oil atomized by the return flow variable capacity atomizer, used with some automatically fired boilers, is controlled by the __________.
- 180.An automatically fired auxiliary boiler is required by Coast Guard Regulations (46 CFR) to be shutdown as a result of __________.
- 181.Fins are installed on the generating tube surfaces in waste heat boilers to __________.
- 182.Subtracting the return flow meter reading from the supply flow meter reading on a boiler equipped with a return flow fuel oil system, determines the amount of oil __________.
- 183.The amount of fuel oil atomized by a return flow oil burner is directly controlled by the __________.
- 184.In a fire-tube auxiliary boiler, you should expect to find the thickest scale on the waterside of the __________.
- 185.The crankcase of many diesel engines are kept under a slight vacuum by the __________.
- 186.Lubricating oil systems for diesel engine journal bearings are usually lubricated by which of the following types of lubricating oil systems?
- 187.When may the crankcase ventilation pipes or oil drain pipes of two or more engines be connected?
- 188.If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be __________.
- 189.When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?
- 190.Which of the following actions should normally be taken during each watch when the auxiliary boiler is in operation?
- 191.Lubrication for the main reduction gears used with diesel engines is usually supplied by __________.
- 192.When there is a flame failure in an automatically fired auxiliary boiler, the __________.
- 193.Excessive vibration of an automatically fired auxiliary boiler can be caused by __________.
- 194.Cooling the intake air supplied to a diesel engine will __________.
- 195.Which of the listed items should be secured before performing any maintenance on a solenoid operated air start valve?
- 196.Burner ignition failure in an automatically fired auxiliary boiler would be caused by __________.
- 197.The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner __________.
- 198.The water in an auxiliary boiler should be tested for chloride content to determine __________.
- 199.What is to be installed on an internal combustion engine if its cylinder bore exceeds eight inches?
- 200.According to Coast Guard Regulations (46 CFR), the fuel strainer installation located in the supply lines to the fuel pump of an auxiliary boiler, can be provided with __________.