If the flame of an automatically fired auxiliary boiler tends to move away from the burner tip when the firing rate is changed from low to high, you should __________.

  1. Adecrease the fuel pressure
  2. Badjust damper linkage to slow the opening rate of the dampers ✓
  3. Cadjust damper linkage to lengthen the purge period
  4. Dadjust the photocell to observe the new flame position

Correct answer: B) adjust damper linkage to slow the opening rate of the dampers

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%