SeaQuiz

When preparing to light off a cold boiler equipped with a return flow fuel oil system, the re-circulating valve directs the flow of oil __________.

  1. Adirectly to the fuel oil heater inlet for further warm-up
  2. Bback to the fuel oil settler for further filtration
  3. Cback to the suction side of the service pump ✓
  4. Ddirectly to the deep tanks

Correct answer: C) back to the suction side of the service pump

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%