USCG Steam Plants – Question Bank Book 13 (BK13) — page 10
1769 questions with correct answers from the official USCG question bank (2008 edition), book 13 (Engine – USCG question bank, 2008 edition, Engine officers). Pass mark 70%. Click a question to see its answer.
Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 901.A power failure in the hydraulic system of a compact type steering gear would cause the rudder to __________.
- 902.Coast Guard Regulations (46 CFR) require that the final setting of boiler safety valves be conducted in presence of the __________.
- 903.Air trapped in the hydraulic fluid of a steering system would be indicated by __________.
- 904.Which of the pumps listed takes fuel oil suction from the double bottom tanks and discharges it to the settling tanks?
- 905.Air trapped in the hydraulic fluid of a steering system would be indicated by __________.
- 906.When air becomes trapped in the hydraulic fluid of a steering system, the __________.
- 907.Which of the following conditions is indicated by the necessity of providing excessive gland sealing steam pressure to maintain the normal operating conditions of the main propulsion unit?
- 908.Damaging scale can form on the interior of superheater tubes as a result of __________.
- 909.While standing watch in the engine room, irregular feeding or surging of the feed water supply to a flash evaporator may be attributed to __________.
- 910.Salinity cells are strategically installed in distilling units to indicate the __________.
- 911.While underway on watch, you notice that you need to constantly increase the coil pressure in the high pressure contaminated evaporator to maintain capacity. Which of the following may be the cause?
- 912.Indicated high salinity of the distillate discharged from a flash-type distilling plant will be a result of __________.
- 913.If a higher than normal water level is observed through the inspection port of a flash evaporator, you should suspect __________.
- 914.Which of the following statements about gravity type lube oil systems is correct?
- 915.Why are scale deposits on the inside of boiler tubes most objectionable?
- 916.An excessively high brine level in a flash evaporator can be caused by __________.
- 917.While standing watch in the engine room, you notice a high reading at a salinity cell located in the loop seal between two stages of a flash type evaporator. This would indicate __________.
- 918.A solenoid valve in the boiler fuel oil supply line will close when the __________.
- 919.While standing watch underway at sea, you notice that the brine level in the second effect of a double effect soloshell evaporator is nearly out the top of the sight glass. Which action should be taken initially?
- 920.Prior to relieving the watch you should first check the fire room status by verifying the boiler water level and ___________.
- 921.Which of the following types of packing is commonly used to seal the glands of an auxiliary turbine?
- 922.High temperature at the superheater outlet would NOT be caused by __________.
- 923.When relieving the watch in the fire room, you should first check the boiler steam pressure and ___________.
- 924.When relieving the watch in the fire room, you should first check the boiler water level and __________.
- 925.When relieving the watch in the fire room, you should first check the fuel pressure to the boiler and __________.
- 926.Prior to relieving the watch you should first check the fire room status by verifying the fuel oil pressure to the boilers and __________.
- 927.The fuel oil meter in the fuel oil service system should be bypassed when __________.
- 928.When relieving the watch in the fire room, you should first check the boiler water level and ___________.
- 929.Prior to relieving the watch at sea, you notice black smoke coming from the stack. What would this indicate?
- 930.When a turbine bearing shows signs of overheating, you should __________.
- 931.Underway on watch in the fire room, the bridge reports black smoke coming from the stack. This would indicate __________.
- 932.When standing watch at sea, steaming full ahead, reducing the boiler forced draft pressure would also have a tendency to correct which discrepancy?
- 933.While standing watch at sea and steaming full ahead, reducing the boiler forced draft pressure would also have a tendency to correct which discrepancy?
- 934.The source of metal particles adhering to the magnets in a lube oil strainer is probably from the __________.
- 935.When standing watch at sea, steaming full ahead, reducing the boiler forced draft pressure would also have a tendency to correct which discrepancy?
- 936.When standing watch at sea, steaming full ahead, reducing the boiler forced draft pressure would also have a tendency to correct which discrepancy?
- 937.When standing watch at sea, steaming full ahead, adding make-up feed water would also have a tendency to change which of the following parameters?
- 938.When standing watch at sea, steaming full ahead, adding make-up feed water would also have a tendency to change which of the following parameters?
- 939.If you are notified that one of the turbine bearings is overheated, which of the following actions should you take first as the watch engineer?
- 940.Air leaks through the inner or outer casings of a boiler will __________.
- 941.When standing watch at sea, steaming full ahead, adding large amounts of make-up feed water would also have a tendency to change which of the following parameters?
- 942.Coast Guard Regulations (46 CFR Part 56) require that new fuel oil service piping between pumps and burners be subjected to __________.
- 943.When standing watch at sea, steaming full ahead, adding make-up feed water from reserve feed double bottom tanks would also have a tendency to change which of the following parameters?
- 944.Excessive water in an operating lube oil system can be detected by __________.
- 945.While underway on watch, you notice that you need to constantly increase the coil pressure in the high pressure contaminated evaporator to maintain capacity. Which of the following may be the cause?
- 946.Condensate from fuel oil heating coils return to the __________.
- 947.To provide emergency feed water supply to a steaming boiler and it becomes necessary to secure the DC heater, suction should be taken on the distilled water tank using the __________.
- 948.The FIRST adverse effect resulting from main bearing wear in an impulse turbine is __________.
- 949.All ships with periodically unattended machinery plants shall, in addition to the general alarm required by Coast Guard Regulations (46 CFR), be provided with a/an __________.
- 950.Which of the following statements represents the Coast Guard Regulation regarding a boiler installation in which the superheater outlet temperature exceeds 850°F?
- 951.All ships with periodically unattended machinery plants shall, in addition to the general alarm required by Coast Guard Regulations (46 CFR), be provided with a/an __________.
- 952.Engineering Control Centers for minimally attended machinery plants shall, in addition to the general alarm required by Coast Guard Regulations (46 CFR), be provided with a/an __________.
- 953.Why are the condensate drains from the fuel oil heaters and fuel oil tank heating coils returned to the drain inspection tank?
- 954.Engineering Control Centers for minimally attended machinery plants shall, in addition to the general alarm required by Coast Guard Regulations (46 CFR), be provided with a/an __________.
- 955.In accordance with Coast Guard Regulations (46 CFR Part 62) for vessels propelled by steam turbines, the navigation bridge primary control system must include safety limit controls for ____________.
- 956.Engineering Control Centers for minimally attended machinery plants shall, in addition to the general alarm required by Coast Guard Regulations (46 CFR), be provided with a/an __________.
- 957.In addition to being hazardous to personnel, gas leaks through the boiler casing can also __________.
- 958.In what classification of steam turbines are the moving blades and the adjacent fixed rows of blades shaped to act as nozzles?
- 959.If the maximum steam generating capacity of a boiler is increased, Coast Guard Regulations (46 CFR) require that the safety valves' __________.
- 960.Which condition could cause a low level in the deaerating feed water tank (DC heater) as the vessel is increasing from maneuvering to sea speed?
- 961.In a propulsion boiler, diesel oil is generally supplied to the burners when __________.
- 962.Turbine blade erosion is accelerated by __________.
- 963.In an oil fired water-tube boiler, inner casing air leaks can cause __________.
- 964.Which of the Coast Guard publications listed contain the information regarding allowable repairs to boilers installed on cargo vessels?
- 965.Many steam plants are designed so that diesel oil can be provided to the burners when __________.
- 966.Which of the journal bearings listed most easily accommodates the minor turbine shaft misalignment?
- 967.Foaming in a lube oil system can cause __________.
- 968.After starting the main lube oil pump in a gravity-type lube oil system, you should verify that the gravity tanks are full by __________.
- 969.Boiler fuel oil atomizer parts should be cleaned by soaking in 'tip cleaner' or diesel fuel and __________.
- 970.Air leaks through the inner or outer casing of a boiler could result in __________.
- 971.Prior to relieving the watch you should first check the fire room status by verifying the boiler water level and __________.
- 972.When relieving the watch in the fire room, you should first check the boiler water level and then ____________.
- 973.To properly clean a burner tip, you should use __________.
- 974.Prior to relieving the watch you should first check the fire room status by verifying the fuel oil pressure to the burners and _____________.
- 975.When relieving the watch in the fire room, you should first check the ___________.
- 976.Which of the conditions listed would indicate water carryover to a turbine?
- 977.Desuperheated steam can be found at the __________.
- 978.According to Coast Guard Regulations (46 CFR), the studs and bolts on marine boiler mountings must be removed for examination at least every __________.
- 979.An unusual vibration in the main propulsion turbine unit, accompanied by a rumbling sound in the reduction gear, could be caused by __________.
- 980.Spray attemperators are commonly used to __________.
- 981.During each two and one-half year inspection, which test or examination of a cargo vessel water tube boiler is required by Coast Guard Regulations (46 CFR)?
- 982.To properly remove the burner tip nut from the burner barrel, the barrel should be __________.
- 983.The main propulsion turbine can be damaged by __________.
- 984.The primary purpose of a control desuperheater installed in the steam drum of a boiler is to __________.
- 985.If oil is observed in the steam drains from a fuel oil heater, you should __________.
- 986.The control desuperheater of most boilers functions to control __________.
- 987.A leaky fuel oil heater relief valve could be indicated by an increase in the __________.
- 988.One function of the desuperheater installed in a boiler steam drum is to __________.
- 989.The MAWP of a boiler is 900 psi and the normal drop across the superheater is 20 psi. If the superheater safety valve is set to lift at 825 psi, the minimum settings of the drum safety valves allowed by Coast Guard Regulations would be __________.
- 990.What will occur if the fuel oil heater condensate returns are not opened or are partially plugged?
- 991.Main reduction and pinion gears are double helically cut to __________.
- 992.A common cause of the babbitt linings cracking in a turbine journal bearing is from __________.
- 993.A boiler superheater safety valve is set to lift at 450 psi (3102 kPa). Coast Guard Regulations (46 CFR) require that if there is a pressure drop of 10 psi (69 kPa) across the superheater, the drum safety valve should set to lift at a pressure of __________.
- 994.If the fuel oil temperature flowing to the burners is too low, the __________.
- 995.If the main propulsion turbine begins to vibrate severely while you are increasing speed, you should __________.
- 996.Coast Guard Regulations (46 CFR) require that alarm systems be provided for superheaters whose operating outlet temperature is capable of exceeding __________.
- 997.What causes carbon to adhere to the inside surfaces of a fuel oil heater?
- 998.Vibration in main propulsion turbines could be caused by __________.
- 999.Desuperheated steam from the control desuperheater is returned to the main superheater to control the outlet temperature by the action of __________.
- 1000.Carbon deposits in a fuel oil heater are caused by __________.