SeaQuiz

The fuel oil meter in the fuel oil service system should be bypassed when __________.

  1. Atransferring fuel from storage to settler tank to avoid erroneous fuel consumption readings
  2. Bconducting programmed routine maintenance of the meter while underway
  3. Cwarming the oil in the burner headers by recirculation prior to boiler light off ✓
  4. Dfinished with engines is given by the bridge

Correct answer: C) warming the oil in the burner headers by recirculation prior to boiler light off

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%