Coast Guard Regulations (46 CFR Part 56) require that new fuel oil service piping between pumps and burners be subjected to __________.

  1. Aa hydrostatic test of 1.5 times the maximum allowable pressure but not less than 500 psi (3447 kPa) ✓
  2. Ba hydrostatic test of 1.25 times the maximum allowable pressure with the relief valves closed
  3. Cspot radiographic examination of portions of the finished weld joints
  4. Da hydrostatic leak test to the design pressure specified by the Coast Guard

Correct answer: A) a hydrostatic test of 1.5 times the maximum allowable pressure but not less than 500 psi (3447 kPa)

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%