Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 1701.While the vessel is rolling in heavy seas, the level in the boiler gage glass remains steady, this is an indication that __________.
- 1702.Which of the following conditions is indicated by an external bulge or bowed area of the boiler furnace wall?
- 1703.Radial cracks have developed in the castable refractory of the burner cones after the first firing since the installation of new furnace front refractory. This is an indication of __________.
- 1704.Coast Guard Regulations (46 CFR) require that in preparing a water-tube boiler for a hydrostatic test, you should fill the boiler with water at a temperature of not less than __________.
- 1705.Waterside grooving is usually very difficult to locate in a boiler tube before leakage occurs because __________.
- 1706.Which of the conditions listed could cause a boiler economizer to leak?
- 1707.When a soot fire occurs, damage to an economizer can be minimized if you __________.
- 1708.Which of the conditions listed would indicate excessive soot buildup on the economizer?
- 1709.Which of the problems listed will occur when the economizer temperature is below the acid dew point of the flue gases?
- 1710.Which of the following would indicate a moderate leak in the desuperheater?
- 1711.A leak in a desuperheater could be indicated by an __________.
- 1712.A small leak in the desuperheater of an operating boiler could cause an __________.
- 1713.A leak in the internal desuperheater located in one of the two main boilers on a ship can be indicated by a/an __________.
- 1714.Leakage into an internal desuperheater may be caused by __________.
- 1715.Which of the conditions listed could be the cause of chattering in a boiler safety valve?
- 1716.While your vessel is underway at normal speed, a steam drum safety valve develops a significant leak. Your first corrective action should be to __________.
- 1717.The MOST common cause of heat blisters developing on boiler generating tubes is due to __________.
- 1718.Blisters developing on boiler tubes can be caused by __________.
- 1719.Heat blisters forming on the first row of the generating tubes are caused by __________.
- 1720.If a large number of tubes has failed, you can minimize damage to a boiler by __________.
- 1721.If a large number of tubes fail in a steaming boiler, the __________.
- 1722.Steam escaping from the boiler casing is a good indication of __________.
- 1723.What is the cause of 'laning' in a boiler tube bank?
- 1724.Fireside burning of boiler tubes is usually the direct result of __________.
- 1725.Which of the following repairs should be made to a badly warped boiler tube?
- 1726.Waterside abrasion of boiler tubes can be caused by __________.
- 1727.The development of pinhole leaks where the boiler tubes enter the water drums and headers, may be evidence of __________.
- 1728.The generating tubes in an operating boiler will overheat and possibly fail when the boiler reaches the end point of __________.
- 1729.Boiler tube failures can result from __________.
- 1730.Cratering and water tracking in boiler tubes is caused by __________.
- 1731.If a tube failure results from low water level and the water level can not be maintained in sight in the gage glass, you should __________.
- 1732.Oil or scale deposits on boiler tube walls will cause __________.
- 1733.Fireside burning of boiler tubes is usually the direct result of __________.
- 1734.Fireside burning of boiler superheater tubes is a direct result of __________.
- 1735.Fireside burning of boiler tubes can be a result of __________.
- 1736.The formation of a pit in the surface of a boiler tube is most likely to occur when __________.
- 1737.If a boiler tube bank baffle carries away, or burns through, there will be __________.
- 1738.Vibration or panting of a boiler can be caused by __________.
- 1739.Pulsating boiler furnace fires can be caused by __________.
- 1740.Panting or rumbling in a boiler furnace is usually caused by __________.
- 1741.If a boiler begins to pant and vibrate you should __________.
- 1742.Which actions listed should be taken if a boiler is panting?
- 1743.If a boiler is panting, which of the following actions should be taken?
- 1744.Panting in an oil fired marine boiler can be caused by __________.
- 1745.If a steaming boiler is not supplied with sufficient air for proper combustion, the __________.
- 1746.If a boiler fire is blown out by a flareback, you should immediately __________.
- 1747.If a major flareback occurs to a boiler, which of the following actions should be immediately taken?
- 1748.When a boiler flareback occurs, you should __________.
- 1749.Gasket leakage around boiler handholes may be caused by __________.
- 1750.If while filling the boiler a newly installed gasket on a water-tube handhole plate weeps, you should __________.
- 1751.Which of the listed methods would be MOST effective when repairing a steam cut on a seating surface of a superheater handhole plate?
- 1752.An indication of a faulty superheater soot blower element is a __________.
- 1753.If a soot blower element does not revolve freely, the most likely cause would be __________.
- 1754.If an oil fire occurs in the double casing of a steaming boiler, you should __________.
- 1755.Excessive soot accumulations on boiler generating tube surfaces can result in __________.
- 1756.Boiler firesides must be kept free of soot accumulations because __________.
- 1757.An indication of excessive soot accumulation on boiler water tubes and economizer surfaces is __________.
- 1758.Which of the listed actions should be carried out with the superheater vent valve during the time steam is being raised in a boiler?
- 1759.The terms 'swell' and 'shrink' relate to a change in boiler water level which __________.
- 1760.During initial starting of the standby turbine-driven feed pump, which of the listed valves should remain closed?
- 1761.No lube oil appearing in the sight glass (bull's eye) of a gravity type system is a positive indication of __________.
- 1762.When starting a turbo generator in an automated plant, you must provide lube oil pressure to the unit by means of a/an __________.
- 1763.Boiler efficiency and its ability to absorb heat is limited by the need to __________.
- 1764.After patching refractory with plastic firebrick, holes are poked in the patch on 1 1/2 inch centers in order to __________.
- 1765.To prevent a small plastic refractory wall patch repair from falling into the furnace of a D-type boiler, you should __________.
- 1766.Circulation in a water-tube boiler is caused by the difference in the __________.
- 1767.To stop the rotor of a main turbine while underway at sea you should __________.
- 1768.If an operating propulsion unit requires excessive quantities of gland sealing steam, you should suspect a __________.
- 1769.When water washing a boiler, the proper sequence for washing the sections should be the __________.