SeaQuiz

The primary purpose of a control desuperheater installed in the steam drum of a boiler is to __________.

  1. Aassure a constant volume of steam flow through the entire superheater under all load conditions
  2. Bregulate the temperature of superheated steam by adding moisture
  3. Cregulate the superheater outlet temperature by cooling a portion of the superheated steam ✓
  4. Dregulate saturated steam temperature through the desuperheater

Correct answer: C) regulate the superheater outlet temperature by cooling a portion of the superheated steam

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%

← PreviousNext →
Take the full practice test: Steam Plants – Question Bank Book 13 →Free USCG practice test with the real pass mark, no sign-up

More questions from this module