Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 701.A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a __________.
- 702.A DC generator which is used to supply direct current in order to maintain an AC generator field is commonly known as a/an __________.
- 703.A volt-ohm-millimeter can be used to check for __________.
- 704.When paralleling two AC generators, the frequency (cycles) of the incoming generator, just prior to closing the circuit breaker, should be __________.
- 705.A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to __________.
- 706.A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to __________.
- 707.Fuses are usually rated in __________.
- 708.When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by __________.
- 709.When paralleled, AC generators must have the same __________.
- 710.Discoloration of the rotor bars in a squirrel-cage motor is typical evidence of __________.
- 711.Multiple grounds have developed and were initially indicated by the ground-detecting system as one ground. The FIRST step in locating the grounds is to __________.
- 712.To protect the rotor of a motor disassembled for maintenance or overhaul, it should be __________.
- 713.Which of the following materials is a good insulator?
- 714.Electrical power is expressed in __________.
- 715.A voltmeter located on a control panel has been operating correctly for six months, suddenly burns out. After removing it, it is found that neither side of the meter has been grounded. When installing the new meter it should be __________.
- 716.Which of the following should be the FIRST step in removing a generator from parallel operation?
- 717.An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel?
- 718.A current-carrying conductor makes accidental contact with a wiring conduit. This will be indicated by a __________.
- 719.An electrical connection between the wiring of an electric motor and its metal frame is known as a/an __________.
- 720.Prior to closing the breaker when paralleling two AC generators, the recommended practice is to have the frequency of the incoming machine __________.
- 721.If a synchronous motor begins to vibrate severely and pull out of synchronism, the cause may be __________.
- 722.Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will __________.
- 723.The standard measuring unit of wire by its cross-sectional area, as used in American wire tables is the __________.
- 724.The effect of carrying field excitation excessively high on a synchronous motor will result in a __________.
- 725.In addition to short circuits and sustained overloads, fuses are likely to blow due to __________.
- 726.The greatest single cause of electrical failures is __________.
- 727.A device used in an electrical circuit to change alternating current to direct current, is known as a __________.
- 728.Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose governor has the zero speed droop setting will __________.
- 729.A fuse will "blow" if __________.
- 730.The inductance of a coil is measured in __________.
- 731.You are reconnecting a three-phase induction motor to the supply line. To prevent possible damage to the load, due to the wrong direction of rotation, you should __________.
- 732.Current flowing in only one direction is called __________.
- 733.An alternator is being paralleled with one on the line. At the INSTANT the circuit breaker is closed, the frequency of the incoming alternator will normally __________.
- 734.If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will __________.
- 735.When a fluorescent lamp fails to light, the trouble can be in the __________.
- 736.Electric current is the flow of electrons through a conductor; the rate of this flow is measured in __________.
- 737.Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators?
- 738.Battery capacities are given in __________.
- 739.When a low input voltage is imparted to a device which then delivers a high output voltage, the device is known as a __________.
- 740.Which of the following conditions can lead to the failure of a resistor?
- 741.A circuit with a blown fuse would be described as a/an __________.
- 742.Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST?
- 743.Routine maintenance of dry-type transformers should include __________.
- 744.The twisting force developed by a motor and applied to a shaft is called __________.
- 745.If field excitation is suddenly lost to an alternator operating in parallel, that alternator will __________.
- 746.Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor?
- 747.Which of the listed devices may be used as a digital device?
- 748.If all of the ground detection lamps burn with equal brilliance, whether the test button is depressed or released, then __________.
- 749.A capacitor discolored due to excessive heat should be __________.
- 750.The unit of electrical power is the __________.
- 751.If the energy input is significantly reduced to the prime mover of one shipboard alternator operating in parallel with others, that alternator will __________.
- 752.Which of the listed procedures is the best way to tell if a motor has become overloaded?
- 753.If a small electric motor is immersed in salt water it should be __________. I. washed in fresh water II. dried in an oven
- 754.In order to change the direction of rotation of a D.C. motor_________. I. the field leads must be changed II. the input leads must be changed
- 755.Some large A.C. motors are equipped with heaters. These could be __________. I. resistance heaters bolted directly to the frame II. low voltage windings embedded in the motor windings
- 756.The unit of electrical resistance is the __________.
- 757.When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the __________.
- 758.Air gap readings should be taken periodically on electrical generation equipment to __________.
- 759.On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. This should be checked with a millivolt meter and a jumper. With the millivolt meter connected between the shaft and the bedplate, how should the jumper be used?
- 760.A current-carrying conductor making electrical contact with a wiring conduit will be indicated by a __________.
- 761.Maintenance of alkaline batteries should include __________.
- 762.If deck machinery is expected to be idle for an extended period of time you should____________.
- 763.Ambient temperature is defined as the __________.
- 764.After closing the circuit breaker to place two similar alternators in parallel, the NEXT step is to balance the __________.
- 765.The failure of ball bearings used in electric motors can result from __________.
- 766.If air gap readings for an electrical generating machine have changed significantly from the last reading, you should check __________.
- 767.A switchboard ammeter indicates a reading slightly above 'zero' when the leads are disconnected, this is caused by __________.
- 768.Air gap readings should be periodically taken for electrical generation equipment. The best tool to use to take these measurements is a __________.
- 769.Air gap readings should be taken on electrical generation equipment periodically to __________. I. check machine efficiency II. determine the need for cleaning
- 770.A circuit that has one of two wires in contact with the hull of a ship, is called a __________.
- 771.Attempting to parallel an AC generator which is out of phase with the bus will result in which of the following problems?
- 772.Air gap readings for electrical generating equipment should be taken periodically. This is to __________. I. determine the condition of the bearings II. prevent damage to the rotor and stator
- 773.Air gap readings should be taken on electrical generation machinery periodically to __________. I. determine the need for cleaning II. check the condition of the bearings
- 774.A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter would then read __________.
- 775.Which of the following statements is true concerning step-down transformer operation?
- 776.To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST __________.
- 777.The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END AFT END Top .045 .049 Right Side .045 .047 Left Side .045 .047 Bottom .045 .041 Which of the following statements is true?
- 778.A ground on a particular phase of a three-phase low voltage distribution system would be indicated by a __________.
- 779.If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should __________.
- 780.Maintenance of alkaline batteries should include __________.
- 781.One item listed on the name plate of a cargo pump motor is 'degrees centigrade rise.' This number is based on __________.
- 782.As part of a routine maintenance program for deck machinery, you should __________.
- 783.Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed?
- 784.A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem probably lies in the __________.
- 785.When testing for blown fuses in a three-phase supply circuit to a motor, you should first __________.
- 786.If your multimeter gives a reading in ohms when testing each end of each conductor of a three-conductor cable, this indicates __________.
- 787.What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip?
- 788.Equalization of the power factors of two alternators operating in parallel is accomplished __________.
- 789.A short circuit in the armature of a DC motor will cause the motor to __________.
- 790.In a three-phase electrical system, three ground detecting lamps are provided. One lamp goes dark and the others increase in brightness when the "ground test" button is pushed. You should conclude that __________.
- 791.Which of the methods listed is used to start a AC generator turning?
- 792.When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is __________.
- 793.In a three-phase electrical system, three ground detecting lamps are provided. If all three lamps REMAIN at half-brilliance when the ground detecting test switch is operated, __________.
- 794.A three-phase alternator is developing 300 amps, with a 0.8 power factor, at 450 volts. The power indicated on the kilowatt meter, located on the main switchboard, will be __________.
- 795.Which of the listed conditions will occur if dirt and grease are allowed to accumulate between the commutator segments of a motor?
- 796.Corrosion-resistant material' and 'non-corrodible material' will include which of the following __________.
- 797.The power supplied to a motor is six kilowatts at 120 volts. What is the impedance of the motor?
- 798.The most effective method of locating a loose commutator bar in a D.C. motor is by __________.
- 799.The distance between a generator and its load is 100 feet. What would be the approximate total voltage drop across a two wire supply cable if the current were 5.5 amperes and the resistance of the wire were 2.525 ohms per 1,000 feet?
- 800.An open armature connection in a DC propulsion motor could be caused by __________.