USCG Deck Safety – Question Bank Book 4 (BK4) — page 41
4852 questions with correct answers from the official USCG question bank (2008 edition), book 4. Pass mark 70%. Click a question to see its answer.
Take the full practice test →Free USCG practice test with the real pass mark, no sign-up- 4001.The signal for fire alarm on a MODU must be indicated __________.
- 4002.The Muster List ("Station Bill") of a MODU must be signed by the __________.
- 4003.What information must be entered on the MODU's muster list?
- 4004.If uniformly distributed in the cantilever pipe rack of the COASTAL DRILLER, how much pipe can be placed in the cantilever pipe rack area when the cantilever has been extended 40 feet aft of the transom?
- 4005.On a vessel of 6500 tons displacement, a tank 35 ft. long, 25 ft. wide, and 8 ft. deep is half filled with liquid cargo (S.G. 1.053) while the vessel is floating in saltwater (S.G. 1.026). What is the free surface constant for this tank?
- 4006.What is the most vulnerable part of the fire main system on board an offshore rig?
- 4007.The relief valve on a fire pump is set at 25 psi above the pressure necessary to maintain required fire streams, or __________.
- 4008.When fire pumps are used for other than firefighting service, each pipe connecting the other service (except for branch lines used for deck washing) must have a __________.
- 4009.A fire main system must have enough fire hydrants so that each accessible space may be sprayed with __________.
- 4010.If the charted water depth is 200 feet, the limits of service for the COASTAL DRILLER require an air gap of __________.
- 4011.Each fire hydrant must have at least one spanner and at least one __________.
- 4012.You are wearing a breathing apparatus inside a tank. How many tugs on the lifeline should you give to indicate that you need help?
- 4013.The size of fire hydrant hose connections must be either 1-1/2 inches or __________.
- 4014.Each fire hydrant serving machinery spaces containing oil fired boilers, internal combustion machinery, or oil fuel units must be equipped with a __________.
- 4015.Each part of the fire-main system located on an exposed deck must be __________.
- 4016.The SS AMERICAN MARINER has drafts of: FWD 25'-11", AFT 26'-11". Use the white pages of the Stability Data Reference Book to determine the drafts if you ballast the forepeak with 83 tons of seawater.
- 4017.Each fire hose coupling on a MODU must have threads that meet the specifications of the __________.
- 4018.Control valves of a CO2 system may be located within the protected space when __________.
- 4019.After using a CO2 extinguisher on a MODU, it should be __________.
- 4020.On a MODU, a CO2 extinguisher is checked by __________.
- 4021.You are wearing a breathing apparatus inside a tank. How many tugs on the lifeline should you give to indicate that you are advancing?
- 4022.A CO2 extinguisher on a MODU which has lost 10% of its charge must be __________.
- 4023.Your drafts are: FWD 25'-09", AFT 28'-03". Use the blue pages of the Stability Data Reference Book to determine the location of the center of flotation relative to amidships.
- 4024.On a MODU, CO2 extinguishers must be weighed __________.
- 4025.The minimum number of portable C-II fire extinguishers required on the drill floor of a MODU is __________.
- 4026.On offshore drilling units, each hand-held portable fire extinguisher, semi-portable fire extinguisher, and fixed fire extinguisher must be tested and inspected at least once every __________.
- 4027.On a MODU, hand portable extinguishers are size(s) __________.
- 4028.On a MODU, size III, IV, and V extinguishers are considered __________.
- 4029.On a MODU, size I and II extinguishers are considered __________.
- 4030.Semi-portable extinguishers used on MODU's are sizes __________.
- 4031.You are in a tank wearing a breathing apparatus and you desire to return topside. How many tugs of the lifeline mean "Take up slack"?
- 4032.On a MODU, an extinguisher with 15 lbs. of CO2 or 10 lbs. of dry chemical is a size __________.
- 4033.On a MODU, firefighting equipment must be inspected once every __________.
- 4034.On a MODU, a fire drill shall be conducted once every __________.
- 4035.During a fire drill on a MODU, what action is required?
- 4036.On a MODU, watertight doors should be operated __________.
- 4037.When testing fire hoses on offshore drilling units, each hose must be subjected to a test pressure of at least __________.
- 4038.On offshore drilling units, the fire main system must have enough fire hydrants so that each accessible space may be sprayed with at least __________.
- 4039.Canvas sails, when not in use, may be damaged if __________.
- 4040.On offshore drilling units, each fire station is required to be fitted with a hose which has a nominal length of __________.
- 4041.While proceeding to a distress site, you hear the words "Seelonce mayday" on the radiotelephone. Which action should you take?
- 4042.The connection facilities for the international shore connection required on board offshore drilling units in international service must be located to provide access __________.
- 4043.How often are fire hoses required to be tested on a mobile offshore drilling unit?
- 4044.The international shore connection required on a MODU is designed to __________.
- 4045.A fire pump on a MODU requires 175 psi discharge pressure to maintain the required 50 psi pitot tube pressure at the two highest hydrants. The maximum setting for the relief valve is __________.
- 4046.On offshore drilling units fitted with fixed CO2 systems, the system must discharge at least 85 percent of the required amount of CO2 within __________.
- 4047.On offshore drilling units fitted with fixed CO2 systems, the system must withstand a bursting pressure of at least __________.
- 4048.Before releasing the CO2 into the space, the alarm for a fixed CO2 system must sound for at least __________.
- 4049.On offshore drilling units fitted with CO2 systems, each space that contains a cylinder must be vented and designed to keep temperature in the space at not more than __________.
- 4050.You are wearing a breathing apparatus inside a tank. How many tugs on the lifeline indicate that you are all right?
- 4051.Operation of the valve control release on a fixed CO2 system must immediately __________.
- 4052.A fixed CO2 system on a MODU with a capacity of over 300 lbs (136 kilograms) CO2 which protects spaces other than tanks must have __________.
- 4053.Your drafts are: FWD 20'-08", AFT 23'-03". Use the blue pages of the Stability Data Reference Book to determine the MT1.
- 4054.On a MODU, a fixed carbon dioxide or other approved system must be installed __________.
- 4055.Portable Halon extinguishers used on MODU's may use __________.
- 4056.What is the meaning of the signal DX RQ when sent by the International Code of Signals?
- 4057.Due to the hazards involved with Halon extinguishers on a MODU, the size II extinguisher may only be used __________.
- 4058.On offshore drilling units where foam systems are installed on the heliport, the system must be able to discharge continuously for at least __________.
- 4059.Where foam extinguishing systems are provided on a MODU, each machinery flat in the protected space must have a(n) __________.
- 4060.What must be provided on a MODU helicopter deck that is equipped with fueling facilities?
- 4061.The primary danger in helicopter fires on a MODU is __________.
- 4062.The preferred agent used in fighting a helicopter crash fire on a MODU is __________.
- 4063.If a mobile offshore drilling rig has four hand portable fire extinguishers that can be recharged by personnel on the unit, how many spare charges must be carried?
- 4064.The inspection of portable extinguishers on a MODU must be __________.
- 4065.On offshore drilling units, the minimum required number of fireman's outfits which must be carried is __________.
- 4066.On a vessel of 7000 tons displacement, a tank 35 ft. long, 30 ft. wide and 4 ft. deep is half filled with fuel oil (S.G. 0.962) while the vessel is floating in saltwater (S.G. 1.026). What is the free surface constant for this tank?
- 4067.What is the minimum required number of fire axes that must be carried on a mobile offshore drilling unit?
- 4068.On offshore drilling units, the minimum number of persons required to be trained in the use of fireman's outfits is __________.
- 4069.How many fireman's outfits are required on a MODU?
- 4070.What equipment is included in the fireman's outfit?
- 4071.Smoking in bed on a MODU is prohibited __________.
- 4072.It is the responsibility of the Master or person in charge of a MODU to ensure that __________.
- 4073.Fires on a MODU must be reported to the Coast Guard if there is death, injury resulting in more than 72 hours incapacitation, or property damage in excess of __________.
- 4074.A fire in a ballast pumproom can be brought under control with minimal impact on stability by __________.
- 4075.Fighting a rig fire in a watertight compartment with hoses could reduce the stability of the rig by __________.
- 4076.What is best suited for fighting a fire in a ballast control room?
- 4077.Each person on the rig has a designated area to proceed to in the event of a fire. This assignment is shown clearly on the rig's __________.
- 4078.You are tending the lifeline of a man who entered a compartment using a breathing apparatus. How many tugs on the lifeline indicate the man should advance?
- 4079.Fighting a rig fire in the ballast pumproom with hoses would adversely affect the stability of the rig most by __________.
- 4080.The two courses of action if the underwater hull of a MODU is severely damaged are to plug the openings and to __________.
- 4081.When patching holes in the hull of a MODU, pillows, bedding, and other soft materials can be used as __________.
- 4082.The procedure of strengthening damaged structures on a MODU by using wood or steel is called __________.
- 4083.When shoring a damaged bulkhead on a MODU, effort should be taken to spread the pressure over the __________.
- 4084.The objective of shoring the damaged area of a MODU is to __________.
- 4085.On board a mobile offshore drilling unit, the key to the most rapid and effective response to a man overboard situation is __________.
- 4086.Repair of structures on a MODU in the vicinity of liquid mud handling areas presents what possible hazard?
- 4087.Your drafts are: FWD 26'-03", AFT 30'-08". Use the blue pages of the Stability Data Reference Book to determine the location of the center of flotation relative to amidships.
- 4088.Explosive and flammable gasses are most likely to be encountered on a MODU __________.
- 4089.The Coast Guard requires machinery spaces and enclosed mud handling spaces to have __________.
- 4090.Control of fire on a MODU should be addressed __________.
- 4091.If there are a number of survivors in the water after abandoning a MODU, they should __________.
- 4092.When should the emergency position-indicating radio beacon be activated after abandoning a MODU?
- 4093.During severe storms when survival becomes a major concern, it may become necessary to relieve high anchor tensions on the windward side of the unit by __________.
- 4094.During storm conditions on a MODU, the mooring tensions should be adjusted so that __________.
- 4095.During a storm, the chance of fatigue failure of a mooring line will increase as __________.
- 4096.During a storm, the mooring line on a MODU should be long enough so that the angle between the anchor shank and the ocean floor is __________.
- 4097.Your drafts are: FWD 17'-09", AFT 18'-03". Use the blue pages of the Stability Data Reference Book to determine the location of the center of flotation relative to amidships.
- 4098.The SS AMERICAN MARINER has drafts of: FWD 22'-03", AFT 26'-05". Use the white pages of the Stability Data Reference Book to determine the drafts if you ballast the forepeak with 77 tons of seawater.
- 4099.When dragging of an anchor occurs, you must either reposition it at greater range or __________.
- 4100.The most doubtful and unpredictable factor in a mooring system is the __________.