F1 Electrical, electronic and control engineering — ETO (CMKE, Poland) — Page 6
586 questions with correct answers. Click a question to see its answer.
Take the full test →Random exam test generator, free, no registration- 501.Cables of networks with a voltage above 1000 V shall be:
- 502.The impact ionization under electric field influence occurs in the event of an impact of:
- 503.Surface ionisation is a phenomenon occurring mainly in the following areas:
- 504.Photoionisation can be classified into:
- 505.The deionisation process consists of:
- 506.What is the measure of polarity of electrical insulating materials?:
- 507.How does conductivity of dielectrics depend on temperature:
- 508.Due to the spatial distribution, stresses can be distinguished as:
- 509.In the case of parallel installation of insulation materials, stress distribution on both sides of the dielectric separation limit is determined as:
- 510.In a flat system of dielectrics arranged in series, the stresses in materials differing in the relative dielectric permeability are associated with the following equation:
- 511.What is the approximate number of free loads in ambient air under average conditions?:
- 512.Cascade discharge in the gas dielectric is initiated by:
- 513.Which of the following mechanisms occur in gases at distances up to 1 cm and atmospheric pressure:
- 514.Critical stress is the value at which:
- 515.The value of the starting voltages of the gas self-discharge determines:
- 516.Which of these types of discharges is not a partial discharge:
- 517.The dielectric resistance of the air at a pressure of 1 atmosphere at 20°C between flat electrodes at a distance of 1 cm is approximately:
- 518.The impact factor for gases is determined by the following equation: U
- 519.At atmospheric pressure, the sulphur hexafluoride (SF6) in relation to air shall have:
- 520.The critical stress of sulphur hexafluoride (SF6) as the pressure increases above atmospheric pressure is subject to the following conditions:
- 521.In which equipment mineral insulating oil is commonly used:
- 522.Synthetic silicone oils in relation to mineral oils show:
- 523.Why electrical insulating oils are generally not used in the shipbuilding industry:
- 524.Bridge mechanism is associated with the presence in dielectric liquid of:
- 525.What breakthrough mechanism will occur in case of long-term permanent dielectric stressing:
- 526.Full discharge (puncture) in the solid dielectric:
- 527.The concept of specific strength refers to:
- 528.The resistance of dielectrics of technical purity is:
- 529.Surface incomplete discharge, in the long term, leads to:
- 530.What kind of electro-isolation system we call non-breakable:
- 531.What is the reason for incomplete discharges on the solid insulation surface:
- 532.How is the intensity of partial discharges (PD) measured in insulation systems?:
- 533.The value of overvoltage is measured by the coefficient of overvoltage determined by the:
- 534.For internal overvoltages, the overvoltage factor is:
- 535.For external overvoltages, the overvoltage factor is included in the range of:
- 536.What circumstances can cause the greatest internal overvoltages:
- 537.Under what conditions can waveforms be generated in electrical power components:
- 538.As the overvoltage wave moves along the power line, it is suppressed:
- 539.The following vessel components are particularly vulnerable to lightning strikes:
- 540.Lightning discharge can be a source of overvoltage:
- 541.When no additional lightning protector installation is required:
- 542.Lightning discharges on a steel hull ship are particularly dangerous for the following installations:
- 543.The following are used as surge protection in the HV power grid:
- 544.At the cable terminals in the ship's HV power grid, the following are used:
- 545.The most commonly used switches in the ship's HV network are:
- 546.In ship's HV switchgears the following is applied:
- 547.Durability of cables designed for high-voltage, alternating current installations:
- 548.The minimum insulation distance in the air between non-insulated rails and metal parts in the rated operating voltage range of electrical equipment from 6 kV to 10 kV shall be as follows:
- 549.Before measuring with the high voltage indicator, there is no need for:
- 550.The limiting sign on the insulating rod is a point:
- 551.Which of the following average stress levels is not currently used on seagoing vessels:
- 552.The aim of the extension or thermoelectric conductors connecting the thermocouple with the transducer or measurement circuit is:
- 553.Static thermocouple characteristics, both in the tabular and analytical forms, are cited in standards in reference to the following temperature of cold ends:
- 554.An operational measurement circuit for the measurement of temperature using a thermocouple after disconnecting conductors and the short-circuiting of clamps of the circuit in which they were connected shows:
- 555.Relevant resistor(s) in the binary measurement path (ON-OFF) with alarm which signals the fault of connecting conductors must be connected:
- 556.Information on a defect in connecting conductors in the binary measurement path (ON-OFF) only in the form of the gap is acquired in the circuit with:
- 557.The thermo-resistor of the sensor Pt-100 is made of:
- 558.The characteristic curve for the thermal resistance sensor Pt-100 in the temperature range between -200oC and 850oC is:
- 559.Sensor Pt-100 has a resistance of 100 [Ω] (ohms) at the temperature of:
- 560.The measurement signal from the thermocouple has:
- 561.Thermoelectric wires are used for the connection of:
- 562.Connection of the sensor Pt-100 to the measurement system or transducer via three or four wires is necessary because of the following:
- 563.Smoke detectors use the following principle of operation
- 564.Operation of the fire thermal detectors is based on:
- 565.The signalling system of the general alarm can be not installed:
- 566.The signalling system of the general alarm can be powered by its battery pack if the following is provided:
- 567.General signalling circuits must be protected against:
- 568.The alarm circuit should trigger the alarm signalling system on the failure of the monitored circuit by:
- 569.Information on momentary alarm conditions (disappearing without any intervention):
- 570.A momentary disruption in the power supply to the alarm circuit:
- 571.The safety circuit of the mechanism should be independent from the following:
- 572.If the safety circuit stops the device, restarting the device is possible:
- 573.Intrinsically safe (spark-proof) accompanying devices are installed in the following:
- 574.The Zener barrier is based on:
- 575.There are two intrinsically safe (spark-proof) electrical devices with the safety levels “a” and “b” Which device provides a higher safety level?
- 576.What kind of devices can be made intrinsically safe (spark-proof):
- 577.Labelling of the electrical device in explosion proof design Ex ia IIC T6 consists of the series of symbols which indicate the following:
- 578.Application of three identical Zener diodes configured in parallel in the intrinsically safe (spark-proof) protective barrier:
- 579.The permitted working plane of the two-wire 4-20mA measurement path describes application properties for the following:
- 580.The serial diode configured in series between the transducer and the measurement circuit:
- 581.The working point of two-conductor current measurement path in 4-20 mA standard is determined by the following coordinates:
- 582.A high resistance of the two-conductor measurement path in 4-20mA standard results, among others, from the following:
- 583.When the transducer is programmed in accordance with Hart Protocol, the programmer must be connected in the transducer circuit compliant with 4-20mA standard so that the minimum resistance of the voltage side is:
- 584.When the programmer communicates with the Hart transducer, there is a reciprocal transmission of the following signals:
- 585.When the intelligent transducer is programmed using the HART programmer, the transducer:
- 586.The following is measured based on the measurement of the hydrostatic pressure in liquid level measurement systems in open tanks: