If you have a duplex double acting reciprocating pump making 150 strokes/minute, with a 3" diameter cylinder, a 11" stroke and operating with 95% volumetric efficiency, what is the capacity of this pump?
- A48 gpm
- B96 gpm ✓
- C176 gpm
- D24 gpm
Correct answer: B) 96 gpm