If you have a duplex double acting reciprocating pump making 110 strokes/minute, with a 6" diameter cylinder, a 7" stroke and operating with 91% volumetric efficiency, what is the capacity of this pump?
- A86 gpm
- B100 gpm
- C172 gpm ✓
- D43 gpm
Correct answer: C) 172 gpm