If you have a duplex single acting reciprocating pump making 110 strokes/minute, with a 3" diameter cylinder, a 5" stroke and operating with 97% volumetric efficiency, what is the capacity of this pump?
- A27 gpm
- B16 gpm ✓
- C8 gpm
- D33 gpm
Correct answer: B) 16 gpm