If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 4" diameter cylinder, a 8" stroke and operating with 94% volumetric efficiency, what is the capacity of this pump?
- A29 gpm
- B57 gpm
- C115 gpm ✓
- D230 gpm
Correct answer: C) 115 gpm