If you have a duplex double acting reciprocating pump making 130 strokes/minute, with a 4" diameter cylinder, a 9" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- A118 gpm ✓
- B59 gpm
- C133 gpm
- D30 gpm
Correct answer: A) 118 gpm