If you have a duplex double acting reciprocating pump making 160 strokes/minute, with a 7" diameter cylinder, a 8" stroke and operating with 97% volumetric efficiency, what is the capacity of this pump?
- A207 gpm
- B236 gpm
- C103 gpm
- D414 gpm ✓
Correct answer: D) 414 gpm