Which of the following conditions is responsible for the fuel oil to atomize when using a steam atomizer in an auxiliary boiler?
- AExpansion of the steam in the furnace. ✓
- BExpansion of the steam in the whirling chamber.
- CExpansion of the steam in the orifice plate.
- DAll of the above.
Correct answer: A) Expansion of the steam in the furnace.