SeaQuiz

Which of the following conditions is the engineer's FIRST warning that the main lube oil pump has stopped?

  1. AGravity tank low level alarm will sound.
  2. BLack of oil in the overflow bull's-eye is observed. ✓
  3. CHigh main engine bearing temperatures will be noted.
  4. DLow main sump level alarm will sound.

Correct answer: B) Lack of oil in the overflow bull's-eye is observed.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%