A water-tube boiler can be laid up either wet or dry. If it is to be laid up wet, you should __________.
- Acompletely fill the boiler with water, then blow down to steaming level
- Bcompletely fill the boiler with deaerated feed water and maintain a slight pressure ✓
- Cdrain and refill the boiler each week
- Ddrain and refill the boiler when the pH goes above 6
Correct answer: B) completely fill the boiler with deaerated feed water and maintain a slight pressure