If you have a duplex double acting reciprocating pump making 140 strokes/minute, with a 4" diameter cylinder, a 7" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- A23 gpm
- B91 gpm ✓
- C45 gpm
- D79 gpm
Correct answer: B) 91 gpm