If you have a duplex double acting reciprocating pump making 160 strokes/minute, with a 4" diameter cylinder, a 10" stroke and operating with 75% volumetric efficiency, what is the capacity of this pump?
- A33 gpm
- B131 gpm
- C65 gpm ✓
- D163 gpm
Correct answer: C) 65 gpm