If you have a duplex double acting reciprocating pump making 130 strokes/minute, with a 6" diameter cylinder, a 5" stroke and operating with 93% volumetric efficiency, what is the capacity of this pump?
- A74 gpm
- B62 gpm
- C148 gpm ✓
- D37 gpm
Correct answer: C) 148 gpm