While on watch, you notice that a significant amount of water is flowing out of the packing box from a centrifugal salt water pump which had been recently overhauled. You tighten the packing gland evenly by nearly a half inch, yet the amount of water output from the packing box does not diminish. You should __________.

  1. Amake no further adjustments and continue to make a round of the engine room
  2. Btake up evenly on the packing gland nuts another 2 or 3 full turns
  3. Cback off on the nuts by the same amount to prevent scoring of the shaft sleeve and notify the next watch of the condition ✓
  4. Dshut off the sealing line valves to diminish the outflow of water from the packing box

Correct answer: C) back off on the nuts by the same amount to prevent scoring of the shaft sleeve and notify the next watch of the condition

USCG question bank (2008) · Engineering General Subjects – Question Bank Book 11 · pass mark 70%