While on watch, you notice that a significant amount of water is flowing out of the packing box from a centrifugal salt water pump which had been recently overhauled. You tighten the packing gland evenly by nearly a half inch, yet the amount of water output from the packing box does not diminish. You should __________.
- Amake no further adjustments and continue to make a round of the engine room
- Btake up evenly on the packing gland nuts another 2 or 3 full turns
- Cback off on the nuts by the same amount to prevent scoring of the shaft sleeve and notify the next watch of the condition ✓
- Dshut off the sealing line valves to diminish the outflow of water from the packing box
Correct answer: C) back off on the nuts by the same amount to prevent scoring of the shaft sleeve and notify the next watch of the condition