If you have a duplex double acting reciprocating pump making 180 strokes/minute, with a 4" diameter cylinder, a 13" stroke and operating with 85% volumetric efficiency, what is the capacity of this pump?
- A108 gpm
- B352 gpm
- C216 gpm ✓
- D54 gpm
Correct answer: C) 216 gpm