If you have a duplex double acting reciprocating pump making 130 strokes/minute, with a 6" diameter cylinder, a 4" stroke with 93% volumetric efficiency, what is the capacity of this pump?
- A59 gpm
- B39 gpm
- C118 gpm ✓
- D30 gpm
Correct answer: C) 118 gpm