SeaQuiz

If the alkalinity of the boiler water is P = 450 PPM calcium carbonate, what will be the adequate actions?

  1. AIncreasing the dosage of added chemicals.
  2. BDecreasing the dosage of added chemicals.
  3. CBlowing down of the boiler and reducing the boiler water treatment chemicals. ✓
  4. DNo action required - alkalinity is beneficial.

Correct answer: C) Blowing down of the boiler and reducing the boiler water treatment chemicals.

← PreviousNext →
Take the full test: F6 Maintenance and Repair — Management Level →Random exam test generator, free, no registration