SeaQuiz

A pilot-operated, main air starting valve begins leaking in one cylinder while the engine is operating. This malfunction is indicated by __________.

  1. Aan increase in the exhaust temperature reading for that cylinder
  2. Ban increase in the starting air manifold pressure
  3. Chigh exhaust pressure
  4. Dan overheated air supply line to that cylinder ✓

Correct answer: D) an overheated air supply line to that cylinder

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%

← PreviousNext →
Take the full practice test: Motor Plants and Auxiliary Boilers – Question Bank Book 14 →Free USCG practice test with the real pass mark, no sign-up