SeaQuiz

A main propulsion diesel engine is fitted with a pneumatically actuated governor, having an operating range of 10 to 60 psig. The current fuel rack setting is 15 mm at 30 psig. If the air pressure to the governor is increased to 40 psig, the fuel rack setting will change to __________.

  1. A10 mm
  2. B14 mm
  3. C15 mm
  4. D20 mm ✓

Correct answer: D) 20 mm

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%

← PreviousNext →