The best method for determining the amount of eccentricity or offset misalignment between the disconnected propeller shaft coupling flange and the reduction gear output flange is by using a __________.

  1. Astraight edge laid across the flange edges
  2. Bthickness gauge between the separated flange faces
  3. Cbridge gauge to check the position of each flange in relation to the other
  4. Ddial indicator mounted on one flange indicating any misalignment of the other flange ✓

Correct answer: D) dial indicator mounted on one flange indicating any misalignment of the other flange

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%