The best method for determining the amount of eccentricity or offset misalignment between the disconnected propeller shaft coupling flange and the reduction gear output flange is by using a __________.
- Astraight edge laid across the flange edges
- Bthickness gauge between the separated flange faces
- Cbridge gauge to check the position of each flange in relation to the other
- Ddial indicator mounted on one flange indicating any misalignment of the other flange ✓
Correct answer: D) dial indicator mounted on one flange indicating any misalignment of the other flange