When the steam pressure drops below a set value on an automatically fired auxiliary boiler, fitted with rotary cup atomizers, the combustion control system will __________.
- Aincrease the fuel oil control valve opening ✓
- Bincrease the rotary cup speed
- Cdecrease the back pressure regulating valve opening
- Ddecrease the supply steam control valve opening
Correct answer: A) increase the fuel oil control valve opening