An 8000 horsepower diesel engine has a specific fuel consumption of 0.4 lbs. of fuel per horsepower hour. If each pound of fuel contains 18,500 BTU's and 25% of the available heat leaves the engine with the exhaust, how many BTU's per hour are theoretically available for use in a waste heat boiler?
- A7.4 million BTU's per hour
- B14.8 million BTU's per hour ✓
- C22.2 million BTU's per hour
- D29.6 million BTU's per hour
Correct answer: B) 14.8 million BTU's per hour