What condition listed below would specifically indicate that a pump overhaul was necessary for a centrifugal saltwater service pump.
- APump coupling requires constant maintenance.
- BObserved operational speed has decreased.
- CIndicated head pressure does not change when discharge valve is closed. ✓
- DSalt water heat exchangers running hot.
Correct answer: C) Indicated head pressure does not change when discharge valve is closed.