SeaQuiz

Which of the following test indicators should be considered the most significant factor in determining as to whether or not a diesel generator's lube oil should be drained and renewed?

  1. AAn extremely high neutralization number. ✓
  2. BAn extremely low precipitation number.
  3. CThe oil appears black in color.
  4. DAn increase in flash point.

Correct answer: A) An extremely high neutralization number.

USCG question bank (2008) · Motor Plants and Auxiliary Boilers – Question Bank Book 14 · pass mark 70%

← PreviousNext →