Which of the following actions should be taken to reestablish a 'blown' air ejector loop seal?

  1. AIncrease the condensate flow through the air ejector.
  2. BMomentarily close the valve in the loop seal line, then reopen slowly. ✓
  3. CShut off the steam to the second stage air ejector momentarily then open it again.
  4. DDecrease the steam pressure to the air ejector nozzles.

Correct answer: B) Momentarily close the valve in the loop seal line, then reopen slowly.