Which of the following statements is correct regarding the start-up operation of a non-condensing turbine-driven feed pump?

  1. AKeep the steam exhaust valve closed until steam is applied to ensure that the auxiliary exhaust line pressure does not drop.
  2. BKeep the pump casing vent valve closed until flow is established through the pump.
  3. COpen the pump suction valve prior to admitting steam to the turbine. ✓
  4. DSecure all drains prior to admitting any steam to avoid damage to traps.

Correct answer: C) Open the pump suction valve prior to admitting steam to the turbine.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%