SeaQuiz

While underway at sea, a mechanical malfunction in one of the ship's service generators operating in parallel, requires that you must secure that generator. In order to prevent a possible overload to the remaining generator, which of the following sequenctial courses of action should be taken?

  1. ATrip the malfunctioning generator's circuit breaker and prime mover throttle trip.
  2. BTrip all non-vital distribution feeder circuit breakers, decrease the load on that generator by using the governor, trip the malfunctioning generator's circuit breaker, and trip the prime mover throttle. ✓
  3. CTrip the malfunctioning generator's circuit breaker and distribution feeder circuit breakers.
  4. DTrip all non-vital distribution feeder circuit breakers, the malfunctioning prime mover turbine throttle trip, and the generator circuit breaker.

Correct answer: B) Trip all non-vital distribution feeder circuit breakers, decrease the load on that generator by using the governor, trip the malfunctioning generator's circuit breaker, and trip the prime mover throttle.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%

← PreviousNext →
Take the full practice test: Steam Plants – Question Bank Book 13 →Free USCG practice test with the real pass mark, no sign-up

More questions from this module

Question list: Steam Plants – Question Bank Book 13 (BK13)