The original bridge gage reading for a reduction gear bearing was measured as .008 inches. A year later, the bridge gage reading for the same bearing is .010 inches. This indicates __________.
- Abearing wear is .010 inch
- Boil clearance is .002 inch
- Cbearing wear is .002 inch ✓
- Doil clearance has increased .010 inch
Correct answer: C) bearing wear is .002 inch