SeaQuiz

According to 46 CFR Part 56, which of the following statements is true concerning the main steam stop valves on multiple boiler installations incorporating uncontrolled superheaters?

  1. AWhen only one valve is used, it must be of the stop-check type.
  2. BThe resistance to closing increases as the cross-sectional area of the valve seat opening decreases.
  3. CA six inch main steam stop must be fitted with a bypass for heating of the line and equalizing the pressure before the valve is opened. ✓
  4. DAll of the above.

Correct answer: C) A six inch main steam stop must be fitted with a bypass for heating of the line and equalizing the pressure before the valve is opened.

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%