Operating a steam turbine propulsion unit at reduced speed, in an area with extremely cold seawater, with the main circulating pump providing full cooling water flow to the condenser will result in __________.
- Adecreased plant efficiency due to higher attainable vacuum
- Bdecreased plant efficiency due to increased condensate depression ✓
- Ca decreased requirement for gland sealing steam
- Dincreased plant efficiency due to increased condensate depression
Correct answer: B) decreased plant efficiency due to increased condensate depression