Your main propulsion boilers are equipped with a two element feed water regulating control system. While on watch, you are required to respond to a 'slow' bell from full sea speed. Under these conditions the automatic feed water regulator will have __________.

  1. Aopened the feed water valve wide due to the effect of shrink
  2. Bclosed down on the feed water valve due to the decrease in steam flow demand ✓
  3. Cpartially closed down on the feed water valve due to the effect of swell
  4. Dfully opened the feed water valve due to the increase in steam flow

Correct answer: B) closed down on the feed water valve due to the decrease in steam flow demand