A steam plant is operating at 100% power when the atmospheric drain tank runs dry allowing a large air leakage into the main condenser. Which of the following will occur as a result of this air leakage?

  1. ADecreased condensate temperature
  2. BDecreased pressure in the main condenser
  3. CDecreased suction pressure at the condensate pump
  4. DDecreased condenser cooling water outlet temperature ✓

Correct answer: D) Decreased condenser cooling water outlet temperature

USCG question bank (2008) · Steam Plants – Question Bank Book 13 · pass mark 70%