Precautions to be observed prior to starting a turbine driven cargo pump, should include __________.
- Aassuring that the turbine casing drains are wired closed
- Bobserving the operation of the over speed trip
- Copen all governor oil relay drains
- Dchecking the manual trip device for proper operation ✓
Correct answer: D) checking the manual trip device for proper operation