SeaQuiz

One method of testing for a reversed shunt field coil in a DC motor is by connecting the coil to a low voltage source, and test for polarity using a/an __________.

  1. Airon bar across each field
  2. Bmagnetic compass placed near each field ✓
  3. Ctest lamp across adjacent fields
  4. Dcopper jumper across the interpole connections

Correct answer: B) magnetic compass placed near each field

USCG question bank (2008) · Electricity – Question Bank Book 12 · pass mark 70%