While troubleshooting a circuit in an engine room central control console, a resistor is suspected of being faulty. Which of the following precautions must be observed if an ohmmeter is to be used to check its value?
- ACorrect polarity must be observed because reverse bias will damage the component.
- BMeter leads must not be twisted so as to cancel out the individual magnetic fields.
- CResistor's circuit must be de-energized and at least one end of the component isolated. ✓
- DThe meter case must be grounded prior to attaching the leads.
Correct answer: C) Resistor's circuit must be de-energized and at least one end of the component isolated.